The blower motor assembly helps move cooled air through the excavator cabin HVAC system. Air enters the HVAC box, passes through the evaporator core, and is then pushed by the blower motor assembly through the air duct and into the cabin outlet. For replacement or bulk sourcing, buyers usually need to compare voltage, airflow, power, size, connector type, and installation space before confirming the right model.
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤7A |
| Speed | ≥3500rpm |
| Air Volume | ≥600m³/h |
| Power | 190W |
| Size | 353×130×108 |
| Connector | DJ7041-6.3-21 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤14A |
| Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 350×167×140 |
| Connector | DJ7021-6.3-11 |
| Application | Delong F3000 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤14A |
| Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 350×167×140 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Gear 1 Load Current | ≤6A |
| Gear 1 Speed | ≥2200rpm |
| Gear 2 Load Current | ≤7A |
| Gear 2 Speed | ≥2600rpm |
| Gear 3 Load Current | ≤9A |
| Gear 3 Speed | ≥3200rpm |
| Gear 4 Load Current | ≤14A |
| Gear 4 Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 345×164×146 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤10A |
| Speed | ≥3900rpm |
| Air Volume | ≥800m³/h |
| Power | 270W |
| Size | 296×133×122.5 |
| Connector | DJ7021-6.3-11 |
| Application | HOWO |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤8A |
| Speed | ≥3600rpm |
| Air Volume | ≥700m³/h |
| Power | 220W |
| Size | 335×141×137 |
| Connector | DJ7021-6.3-11 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Gear 1 Load Current | ≤5A |
| Gear 1 Speed | ≥2200rpm |
| Gear 2 Load Current | ≤6A |
| Gear 2 Speed | ≥2600rpm |
| Gear 3 Load Current | ≤8A |
| Gear 3 Speed | ≥3200rpm |
| Gear 4 Load Current | ≤13A |
| Gear 4 Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 330W |
| Size | 320×184×157 |
| Connector | DJ7061-6.3-11 |
| Application | New BEIBEN Model |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤9A |
| Speed | ≥4500rpm |
| Air Volume | ≥650m³/h |
| Power | 250W |
| Size | 350×160×140 |
| Application | Golden Prince |
| Test Voltage | 13.5/27V |
| Static Pressure | 0Pa |
| Load Current | ≤8A / 5A |
| Speed | ≥3200rpm |
| Air Volume | ≥500m³/h |
| Power | 140W |
| Size | 262×137.5×126 |
| Connector | DJ7021-6.3-11 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| M Gear Load Current | ≤14A |
| M Gear Speed | ≥3700rpm |
| L Gear Load Current | ≤6A |
| L Gear Speed | ≥3200rpm |
| H Gear Load Current | ≤7A |
| H Gear Speed | ≥3000rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 350×136×140 |
| Connector | DJ7041-6.3-11 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤14A |
| Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 367×166×141 |
| Connector | DJ7021-6.3-11 |
| Application | Passenger Compartment Defroster |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤6A |
| Speed | ≥4000rpm |
| Air Volume | ≥640m³/h |
| Power | 160W |
| Size | 310×128×112 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Gear 1 Load Current | ≤3.5A |
| Gear 1 Speed | ≥2900rpm |
| Gear 2 Load Current | ≤4.5A |
| Gear 2 Speed | ≥2900rpm |
| Gear 3 Load Current | ≤5A |
| Gear 3 Speed | ≥3600rpm |
| Gear 4 Load Current | ≤6A |
| Gear 4 Speed | ≥4000rpm |
| Air Volume | ≥640m³/h |
| Power | 160W |
| Size | 310×128×112 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤14A |
| Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 345×164×146 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Gear 1 Load Current | ≤6A |
| Gear 1 Speed | ≥2200rpm |
| Gear 2 Load Current | ≤7A |
| Gear 2 Speed | ≥2600rpm |
| Gear 3 Load Current | ≤9A |
| Gear 3 Speed | ≥3200rpm |
| Gear 4 Load Current | ≤14A |
| Gear 4 Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 335×164×146 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤16A |
| Speed | ≥3600rpm |
| Air Volume | ≥800m³/h |
| Power | 430W |
| Size | 328×190×148 |
| Connector | DJ7021-6.3-11 |
| Application | Shaanxi Auto Delong |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤9A |
| Speed | ≥4500rpm |
| Air Volume | ≥650m³/h |
| Power | 250W |
| Size | 350×145×162 |
| Application | Steyr King / HOWO |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤7A |
| Speed | ≥3500rpm |
| Air Volume | ≥600m³/h |
| Power | 190W |
| Size | 353×130×108 |
| Connector | DJ7021-6.3-11 |
| Application | Delong Kinglong Yutong |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Gear 1 Load Current | ≤6A |
| Gear 1 Speed | ≥2200rpm |
| Gear 2 Load Current | ≤7A |
| Gear 2 Speed | ≥2600rpm |
| Gear 3 Load Current | ≤8A |
| Gear 3 Speed | ≥3200rpm |
| Gear 4 Load Current | ≤14A |
| Gear 4 Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 350×167×140 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Gear 1 Load Current | ≤6A |
| Gear 1 Speed | ≥2200rpm |
| Gear 2 Load Current | ≤7A |
| Gear 2 Speed | ≥2600rpm |
| Gear 3 Load Current | ≤8A |
| Gear 3 Speed | ≥3200rpm |
| Gear 4 Load Current | ≤14A |
| Gear 4 Speed | ≥3700rpm |
| Air Volume | ≥1000m³/h |
| Power | 380W |
| Size | 350×167×140 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤8A |
| Speed | ≥3600rpm |
| Air Volume | ≥700m³/h |
| Power | 220W |
| Size | 330×141×122 |
| Connector | DJ7021-6.3-11 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤8A |
| Speed | ≥3600rpm |
| Air Volume | ≥700m³/h |
| Power | 220W |
| Size | 335×141×137 |
| Connector | DJ7021-6.3-11 |
| Application | Radiator |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤14A |
| Speed | ≥3300rpm |
| Air Volume | ≥900m³/h |
| Power | 380W |
| Size | 330×188×156 |
| Application | SINOTRUK HOWO A7 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤13A |
| Speed | ≥3300rpm |
| Air Volume | ≥600m³/h |
| Power | 350W |
| Size | 346×205×172 |
| Connector | DJ7021-6.3-11 |
| Application | Foton GTL |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤9A |
| Speed | ≥4500rpm |
| Air Volume | ≥650m³/h |
| Power | 250W |
| Size | 350×145×162 |
| Application | Steyr King / HOWO |
| Test Voltage | 13.5V |
| Static Pressure | 0Pa |
| Load Current | ≤7A |
| Speed | ≥3500rpm |
| Power | 100W |
| Size | 298×82×96.5 |
| Application | Hyundai Mini Excavator |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤9A |
| Speed | ≥3300rpm |
| Power | 240W |
| Size | 315×105×89 |
| Connector | DJ214Y-2-11 |
| Application | Volvo |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤5A |
| Speed | ≥3500rpm |
| Power | 140W |
| Size | 285×89×81 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤7A |
| Speed | ≥3500rpm |
| Power | 190W |
| Size | 292×110×81 |
| Connector | DJ7022-6.3-11 |
| Application | Komatsu-70 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤9A |
| Speed | ≥3700rpm |
| Power | 240W |
| Size | 308.5×105×89 |
| Test Voltage | 27V |
| Voltage Range | 16-32VDC |
| Static Pressure | 0Pa |
| Load Current | ≤16A |
| Speed | 1000-4100rpm |
| Max Air Volume | ≥1200m³/h |
| Power | 430W |
| Size | 351×136×140 |
| Control System | PWM / Analog Voltage |
| EMC | Level 3 |
| Test Voltage | 27V |
| Static Pressure | 0Pa |
| Load Current | ≤13A |
| Speed | 900-3650rpm |
| Max Air Volume | ≥1100m³/h |
| Power | 350W |
| Size | 351×136×140 |
| Connector | AMP282106-1 |
| Control System | PWM / Analog Voltage |
| EMC | Level 3 |
To help confirm the right blower motor assembly, please provide as much information as possible, such as voltage, power, airflow, speed, dimensions, connector type, installation space, and product photos.
If you are sourcing for excavator cabin HVAC systems or other construction machinery applications, application details and expected order quantity are also helpful. This allows Elecdura to recommend suitable products and provide more accurate quotation support.
Yes. Elecdura supports sourcing for blower motor assemblies, evaporator blower fans, and related cooling system parts for importers, wholesalers, aftermarket distributors, and construction machinery parts suppliers.
For bulk inquiries, customers can send the required model list, technical parameters, pictures, target quantity, and application information. Our team can help check available options and prepare a quotation based on the selected models.
Yes, different blower motor assemblies may be available for 12V, 24V, or 48V systems, depending on the model. In construction machinery and off-highway applications, 24V systems are especially common, while some newer or special systems may use different voltage ranges.
When comparing products, buyers should check both the system voltage and the test voltage information. This helps avoid confusion between standard vehicle electrical systems and laboratory testing conditions.
Buyers should compare the main technical specifications before confirming a model. Important factors include system voltage, power, speed, airflow, load current, product size, connector type, and installation space.
For excavator cabin HVAC systems, airflow performance and mounting dimensions are especially important. If the blower size or outlet direction does not match the HVAC box, the unit may not install or perform properly.
Elecdura covers several blower-related products for cabin HVAC and air conditioning systems, including housed blower motor assemblies, open-type evaporator blower fans, and brushless / BLDC blower motor assemblies.
Housed types are commonly selected for ducted HVAC systems. Open-type designs are used where the fan layout is more exposed or space-specific. Brushless blower assemblies are suitable for applications requiring more stable speed control, wider voltage range, or longer service life.
A blower motor assembly normally refers to a more complete unit, often with a housing, motor, fan wheel, and mounting structure. It is commonly used in cabin HVAC systems where airflow needs to be guided through ducts.
An evaporator blower fan may refer to the fan used near the evaporator side of the A/C system. Some designs are open-type fan assemblies, while others are housed units. The correct choice depends on the HVAC layout, installation space, airflow requirement, and electrical parameters.
A housed blower motor assembly usually combines a motor, fan wheel, housing, and airflow channel in one unit. When the motor runs, the blower wheel rotates and creates airflow inside the housing.
The air is directed through the HVAC duct system and delivered to the cabin outlets. For construction machinery, the housing design helps guide airflow more efficiently and makes the blower easier to install inside the cabin HVAC box or air conditioning unit.
A blower motor assembly is used to move air through the cabin HVAC system. In an excavator or construction machinery cab, air passes through the evaporator core and is then pushed by the blower motor assembly through the air ducts and cabin outlets.
This component helps maintain stable airflow inside the operator cabin and supports the performance of the air conditioning system, especially in dusty, hot, or long-hour working environments.
Get the complete product data sheet for available blower motor assemblies and evaporator blower fans. You can use the catalog to check:
- Available housed blower motor assemblies
- Open-type evaporator blower fan options
- 12V, 24V and 48V specifications
- Airflow, power, speed and size differences
- Connector and installation reference details